Lifetime Connectivity

RSB-12
RSB-Clip

Rev : H | Rev date : 05 Mar 2026

RSB -Clip Stainless Steel Hanger . Quantity of cable gripping tabs for the various cable type may be different.

Features / Benefits

The RSB-Clip is designed for the installation of feeder cables from sizes 1/4"up to 1-5/8". The clip is a universal clamp device and can be used in many mounting configuration. The RSB-Clip is made of stainless steel. The hanger is resistant against all environmental influences. Due to the mechanical construction, a cable deformation is impossible. Therefore, a deterioration of the electrical properties is avoided.

rsb-12_ti.png
General Specifications
Product Type Hanger
Hanger Type RSB-Clip
Cable Type Coaxial Foam Dielectric, Radiating Cable, Hybrid
Mechanical Specifications
Cable Size 1/2
Number of Cable / Waveguide Runs 1
Material

Stainless Steel

Drill Hole Size 8mm (0.315in)
Testing and Environmental
Installation Temperature -50°C to 85°C (-58°F to 185°F)
Operation Temperature -50°C to 85°C (-58°F to 185°F)
Storage Temperature -50°C to 85°C (-58°F to 185°F)

Related Products


RLK12-50CPR

Size
1/2
Max. Operating Frequency
980MHz
Impedance - Number
50
Impedance - Tolerance
2
Jacket
CPR, EN50575:2014 + A1:2016 classified cable
Jacket Description
Halogen free, non corrosive, flame and fire retardant, low smoke, polyolefin + flame barrier tape above outer conductor for lowest cable loss
Slot Design
Groups of vertical slots at short intervals
Frequency Selection
600
900
Request quote
Discontinued

RLK12-50JFLA

Size
1/2
Max. Operating Frequency
980MHz
Impedance - Number
50
Impedance - Tolerance
2
Jacket
JFL
Jacket Description
Halogen free, non corrosive, flame and fire retardant, low smoke, polyolefin + flame barrier tape above outer conductor for lowest cable loss
Slot Design
Groups of vertical slots at short intervals
Frequency Selection
600
900
Request quote

RLKD12-50CPR

Size
1/2
Impedance - Number
50
Impedance - Tolerance
2
Jacket
CPR, EN50575 classified cable
Jacket Description
Halogen free, non corrosive, flame and fire retardant, low smoke, polyolefin + flame barrier tape above outer conductor for lowest cable loss
Slot Design
Groups of vertical slots at short intervals
Frequency Selection
600
900
1800/1900
2200
2400
2500
2700
6000
Request quote

RLKAX12-50JFNA

Size
1/2
Impedance - Number
50
Impedance - Tolerance
2
Jacket
JFN
Jacket Description
Halogen free, non corrosive, flame and fire retardant, low smoke, polyolefin
Slot Design
Groups of vertical slots at short intervals
Frequency Selection
2400
2600
3500
3800
4200
4900
5800
7000
Request quote