7/8" CELLFLEX® Lite Low-Loss Foam-Dielectric Coaxial Cable, Flame Retardant Jacket

Rev : A | Rev date : 08 Jan 2026

CELLFLEX® Lite 7/8" low loss cable

Features / Benefits

  • Ultra Low Attenuation
    The reduced attenuation of CELLFLEX® coaxial cable results in extremly efficient signal transfer in your RF
    system, especially at high frequencies.
  • Complete Shielding
    The solid outer conductor of CELLFLEX® coaxial cable creates a continuous RFI/EMI shield that minimizes
    system interference.
  • Low VSWR
    Special low VSWR versions of CELLFLEX® coaxial cables contribute to low system noise.
  • Outstanding Intermodulation Performance
    CELLFLEX® coaxial cable's solid inner and outer conductors virtually eliminate intermods. Intermodulation
    performance is also confirmed with state-of-the-art equipment at the RFS factory.
  • High Power Rating
    Due to their low attenuation, outstanding heat transfer properties and temperature stabilized dielectric
    materials, CELLFLEX® cable provides safe long term operating life at high transmit power levels.
  • Wide Range of Application
    Typical areas of application are: feedlines for broadcast and terrestrial microwave antennas, wireless
    cellular, PCS and ESMR base stations, cabling of antenna arrays, and radio equipment interconnects.
lcf78-50jl.png
Structure
Cable Type LCF
Size 7/8"
Jacket Option Indoor
Inner Conductor Material Copper Tube
Dielectric Material Foam Polyethylen
Outer Conductor Material Corrugated Aluminium
Jacket Material Black Polyethylen, Metalhydroxite Filling
Mechanical Specification
Inner Conductor Diameter 9.32mm (0.367in)
Dielectric Diameter 21.5mm (0.846in)
Outer Conductor Diameter 25.2mm (0.992in)
Jacket Diameter 27.8mm (1.094in)
Cable Weight 0.39kg/m (0.262lb/ft)
Min. Bending Radius, Single Bend 120mm (5in)
Min. Bending Radius, Repeated Bends 250mm (10in)
Bending Moment 13Nm (9.594ft-lbf)
Tensile Strength 1,440N (324lb)
Max. Pulling Length per Hoisting Grip 60m (2,362.205in)
Recommended Clamp Spacing 0.8m (2.625ft)
Max. Clamp Spacing 1m (3.281ft)
Electrical Specification
Impedance 50 ±1 Ω
Max. Operating Frequency 5 GHz
Velocity 90 %
Capacitance 75pF/m (22.9pF/ft)
Peak Power Rating 85 kW
RF Peak Voltage 2.92 kV
Jacket Spark 5 kV
DC-Resistance Inner Conductor 2.04Ω/km (0.622Ω/kft)
DC-Resistance Outer Conductor 1.42Ω/km (0.433Ω/kft)
Return Loss (VSWR) Performance Standard 20dB (1.222) / Premium 23/24dB (1.152/1.135) on specified frequencies.
Testing and Environmental
Fire Performance Flame Retardant, Halogen Free, Low Smoke
Compliance RoHS 2011/65/EU
China RoHS SJ/T 11364-2006
REACH (EC 1907/2006)
IEC 60754-1/-2 Halogen Acid Gases
IEC 60332-1 Single-Cable Flame Test
IEC 61034-1, -2 Smoke Density Measurement
Installation Temperature, Minimum -25°C (-13°F)
Installation Temperature, Maximum 60°C (140°F)
Storage Temperature, Minimum -70°C (-94°F)
Storage Temperature, Maximum 85°C (185°F)
Operation Temperature, Minimum -50°C (-58°F)
Operation Temperature, Maximum 85°C (185°F)
ATTENUATION AND POWER RATING
Frequency, MHz dB per 100m dB per 100ft Power, kW
88 1.18 0.36 8.98
100 1.26 0.384 8.41
150 1.55 0.473 6.84
200 1.8 0.549 5.89
450 2.74 0.837 3.87
700 3.46 1.06 3.06
800 3.72 1.13 2.85
894 3.95 1.2 2.68
900 3.96 1.21 2.68
960 4.1 1.25 2.59
1800 5.76 1.76 1.84
2000 6.1 1.86 1.74
2200 6.43 1.96 1.65
2400 6.75 2.06 1.57
2600 7.05 2.15 1.5
2700 7.2 2.2 1.47
3000 7.64 2.33 1.39
3500 8.33 2.54 1.27
4000 8.98 2.74 1.18
5000 10.2 3.11 1.04
Note Standard Conditions:
For attenuation: VSWR 1.0, cable temperature 20°C (68°F).
For average power: VSWR 1.0, ambient temperature 40°C (104°F), inner conductor temperature 100°C (212°F). No solar loading.