Lifetime Connectivity

HCA78-50JFN
7/8" HELIFLEX® Air-Dielectric Coaxial Cable, flame retardant/ halogen free jacket

Rev : B | Rev date : 15 Jan 2026

HELIFLEX® 7/8" low loss air dielectric cable

Features / Benefits

  • Low Attenuation
    The low attenuation of HELIFLEX® coaxial cable results in highly efficient signal transfer in your RF system.
  • Complete Shielding
    The solid outer conductor of HELIFLEX® coaxial cable creates a continuous RFI/EMI shield that minimizes system interference.
  • Low VSWR
    Special low VSWR versions of HELIFLEX® coaxial cables contribute to low system noise.
  • Outstanding Intermodulation Performance
    HELIFLEX® coaxial cable's solid inner and outer conductors virtually eliminate intermods. Intermodulation performance is also confirmed with state-of-the-art equipment at the RFS factory.
  • High Power Rating
       Due to their low attenuation, outstanding heat transfer properties and temperature stabilized dielectric
    materials, HELIFLEX® cable provides safe long term operating life at high transmit power levels.
  • Wide Range of Application
    Typical areas of application are: feedlines for broadcast and terrestrial microwave antennas, wireless cellular, PCS and ESMR base stations, cabling of antenna arrays, and radio equipment interconnects.
hca118.png
Applications
Applications Wireless Communication TV & Radio HF Defense Mobile Radio Cable Solutions
Structure
Cable Type HCA
Size 7/8"
Jacket Option Indoor
Inner Conductor Material Copper Tube
Dielectric Material Helical Polyethylene Spacer
Outer Conductor Material Corrugated Copper
Jacket Material Black Polyethylene, Metalhydroxite Filling
Mechanical Specifications
Inner Conductor Diameter 9mm (0.35in)
Dielectric Diameter 20.2mm (0.79in)
Outer Conductor Diameter 25.5mm (1in)
Jacket Diameter 28mm (1.103in)
Cable Weight 0.68kg/m (0.46lb/ft)
Min Bending Radius, Single Bend 100mm (4in)
Min. Bending Radius, Repeated Bends 250mm (10in)
Bending Moment 27 Nm (20 lbf*ft)
Tensile Strength 1,600N (360lb)
Air Volume 0.34l/m (0.0037ft³/ft)
Recommended / Maximum Clamp Spacing 0.5 / 0.9 m (1.8 / 3 ) ft
Electrical Specifications
Impedance 50 +/- 0.5 Ω
Max. Operating Frequency 3 GHz
Velocity 93 %
Capacitance 71pF/m (21.6pF/ft)
Inductance 0.178µH/m (0.054µH/ft)
Peak Power Rating 73 kW
RF Peak Voltage 2,700 V
Jacket Spark 8,000 V RMS
DC-Resistance Inner Conductor 1.1Ω/km (0.34Ω/kft)
DC-Resistance Outer Conductor 0.88Ω/km (0.27Ω/kft)
Return Loss (VSWR) Performance Standard
Min. Return Loss (Max. VSWR) Typical 20.8dBdB (1.2 VSWR or better within the operation bands of most global frequency ranges. Premium also available. Contact factory for options in your specific frequency band.VSWR)
Testing and Environmental
Fire Performance Flame Retardant, Halogen Free, Low Smoke
Compliance

RoHS 2011/65/EU
China RoHS SJ/T 11364-2006
IEC 60754-1/-2 Halogen Acid Gases
REACH (EC 1907/2006)
IEC 60332-1 Single-Cable Flame Test
IEC 61034-1, -2 Smoke Density Measurement
EN 50575:2014 + A1:2016 Construction Products Regulation

Phase Stabilized

Phase stabilized and phase matched cables and assemblies are available upon request.

Installation Temperature -40°C to 60°C (-40°F to 140°F)
Storage Temperature -70°C to 85°C (-94°F to 185°F)
Operation Temperature -50°C to 85°C (-58°F to 185°F)
Attenuation and Power Rating
Frequency, MHz dB per 100m dB per 100ft Power, kW
0.5 0.081 0.025 73
1 0.115 0.035 73
1.5 0.141 0.043 70.9
2 0.163 0.05 61.4
10 0.366 0.112 27.3
20 0.52 0.158 19.2
30 0.638 0.194 15.7
50 0.827 0.252 12.1
88 1.1 0.337 9.11
100 1.18 0.359 8.49
108 1.23 0.374 8.15
150 1.45 0.443 6.92
174 1.57 0.478 6.39
200 1.69 0.514 5.94
300 2.08 0.634 4.84
400 2.42 0.738 4.17
450 2.57 0.785 3.93
500 2.72 0.83 3.71
512 2.76 0.84 3.66
600 3 0.914 3.37
700 3.25 0.992 3.12
800 3.49 1.07 2.91
824 3.55 1.08 2.86
894 3.71 1.13 2.74
900 3.72 1.13 2.74
925 3.78 1.15 2.69
960 3.85 1.17 2.65
1000 3.94 1.2 2.59
1250 4.45 1.36 2.3
1500 4.91 1.5 2.1
1700 5.26 1.6 1.97
1800 5.43 1.65 1.91
2000 5.75 1.75 1.81
2200 6.07 1.85 1.72
2300 6.22 1.9 1.68
3000 7.22 2.2 1.47
Note Standard Conditions:
For attenuation: VSWR 1.0, cable temperature 20°C (68°F).
For average power: VSWR 1.0, ambient temperature 40°C (104°F), inner conductor temperature 115°C (239°F). No solar loading.

External Document Links

Notes

Related Products


HCH-78-1C

Hanger Type
Anchor bar 18-22mm (0.71-0.87")
Cable Type
Air Dielectric
Coaxial Foam Dielectric
Cable Size
7/8
Request quote

HCH-78-1L4

Hanger Type
Angle iron 40mm (1.575")
Cable Type
Air Dielectric
Coaxial Foam Dielectric
Cable Size
7/8
Request quote

HCH-78-1R

Hanger Type
Flat iron 6-12mm (0.24-0.47")
Cable Type
Air Dielectric
Coaxial Foam Dielectric
Cable Size
7/8
Request quote

EAR-78

Type of Grounding Kit
Pre-Formed Copper Strap
Package Quantity
1
Request quote

HCA78-50J

Applications
Wireless Communication
TV & Radio
HF Defense
Mobile Radio
Cable Solutions
Jacket Option
Outdoor
Fire Performance
Halogene Free
Request quote

HCH-78-1C

Hanger Type
Anchor bar 18-22mm (0.71-0.87")
Cable Type
Air Dielectric
Coaxial Foam Dielectric
Cable Size
7/8
Request quote

HCH-78-1L4

Hanger Type
Angle iron 40mm (1.575")
Cable Type
Air Dielectric
Coaxial Foam Dielectric
Cable Size
7/8
Request quote

HCH-78-1R

Hanger Type
Flat iron 6-12mm (0.24-0.47")
Cable Type
Air Dielectric
Coaxial Foam Dielectric
Cable Size
7/8
Request quote

EAR-78

Type of Grounding Kit
Pre-Formed Copper Strap
Package Quantity
1
Request quote
Discontinued

HOIST1-78C

Cable Size
7/8"
Product Type
Hoisting Grip
Request quote

HCA78-50J

Applications
Wireless Communication
TV & Radio
HF Defense
Mobile Radio
Cable Solutions
Jacket Option
Outdoor
Fire Performance
Halogene Free
Request quote

RSB-315

Hanger Type
RSB clamping plate for anchor bar
Cable Type
Coaxial Foam Dielectric
Elliptical Waveguide
Request quote

RSB-310

Hanger Type
RSB Cleat
Cable Type
Coaxial Foam Dielectric
Request quote

RSB-78

Hanger Type
RSB-Clip
Cable Type
Coaxial Foam Dielectric
Air Dielectric
Cable Size
7/8
Request quote
Discontinued

HOIST1-78C

Cable Size
7/8"
Product Type
Hoisting Grip
Request quote