Lifetime Connectivity

HCA550-50JFN
5-1/2" HELIFLEX® Air-Dielectric Coaxial Cable, flame retardant/ halogen free jacket

Rev : G | Rev date : 15 Jan 2026

HELIFLEX® 5-1/2" low loss air dielectric cable; flame retardant/ halogen free jacket

Features / Benefits

  • Low Attenuation
    The low attenuation of HELIFLEX® coaxial cable results in highly efficient signal transfer in your RF system.
  • Complete Shielding
    The solid outer conductor of HELIFLEX® coaxial cable creates a continuous RFI/EMI shield that minimizes system interference.
  • Low VSWR
    Special low VSWR versions of HELIFLEX® coaxial cables contribute to low system noise.
  • Outstanding Intermodulation Performance
    HELIFLEX® coaxial cable's solid inner and outer conductors virtually eliminate intermods. Intermodulation performance is also confirmed with state-of-the-art equipment at the RFS factory.
  • High Power Rating
       Due to their low attenuation, outstanding heat transfer properties and temperature stabilized dielectric
    materials, HELIFLEX® cable provides safe long term operating life at high transmit power levels.
  • Wide Range of Application
    Typical areas of application are: feedlines for broadcast and terrestrial microwave antennas, wireless cellular, PCS and ESMR base stations, cabling of antenna arrays, and radio equipment interconnects.
hca300-50j.png
Applications
Applications TV & Radio HF Defense Cable Solutions
Structure
Cable Type HCA
Size 5-1/2"
Jacket Option Indoor
Inner Conductor Material Corrugated Copper Tube
Dielectric Material Helical Polyethylene Spacer
Outer Conductor Material Corrugated Copper
Jacket Material Black Polyethylene, Metalhydroxite Filling
Mechanical Specifications
Inner Conductor Diameter 58mm (2.28in)
Dielectric Diameter 127mm (5in)
Outer Conductor Diameter 140.5mm (5.53in)
Jacket Diameter 147.1mm (5.79in)
Cable Weight 7.5kg/m (5lb/ft)
Min Bending Radius, Single Bend 800mm (31in)
Min. Bending Radius, Repeated Bends 1,500mm (59in)
Bending Moment 580 Nm (428 lbf*ft)
Tensile Strength 4,000N (900lb)
Air Volume 14l/m (0.1507ft³/ft)
Recommended / Maximum Clamp Spacing 1 / 2 m (3.3 / 6.6 ) ft
Electrical Specifications
Impedance 50 +/- 0.5 Ω
Max. Operating Frequency 0.86 GHz
Velocity 96 %
Capacitance 70pF/m (21.3pF/ft)
Inductance 0.175µH/m (0.053µH/ft)
Peak Power Rating 2,250 kW
RF Peak Voltage 15,000 V
Jacket Spark 8,000 V RMS
DC-Resistance Inner Conductor 0.2Ω/km (0.06Ω/kft)
DC-Resistance Outer Conductor 0.057Ω/km (0.017Ω/kft)
Return Loss (VSWR) Performance Standard
Min. Return Loss (Max. VSWR) Typical 20.8dBdB (1.2 VSWR or better within the operation bands of most global frequency ranges. Premium also available. Contact factory for options in your specific frequency band.VSWR)
Testing and Environmental
Fire Performance Flame Retardant, Halogen Free, Low Smoke
Compliance

RoHS 2011/65/EU
China RoHS SJ/T 11364-2006
IEC 60754-1/-2 Halogen Acid Gases
REACH (EC 1907/2006)
IEC 60332-1 Single-Cable Flame Test
IEC 61034-1, -2 Smoke Density Measurement
EN 50575:2014 + A1:2016 Construction Products Regulation

Phase Stabilized Phase matched cables and assemblies are available upon request.
Installation Temperature -25°C to 60°C (-13°F to 140°F)
Storage Temperature -70°C to 85°C (-94°F to 185°F)
Operation Temperature -50°C to 85°C (-58°F to 185°F)
Attenuation and Power Rating
Frequency, MHz dB per 100m dB per 100ft Power, kW
0.5 0.015 0.005 1890
1 0.021 0.006 1330
1.5 0.026 0.008 1090
2 0.03 0.009 940
10 0.067 0.021 418
20 0.096 0.029 294
30 0.118 0.036 239
50 0.153 0.047 184
88 0.205 0.062 138
100 0.219 0.067 129
108 0.228 0.069 124
150 0.27 0.082 105
174 0.292 0.089 97.7
200 0.314 0.096 91.1
300 0.39 0.119 74
400 0.455 0.139 64
450 0.485 0.148 60.3
500 0.513 0.156 57.2
512 0.52 0.158 56.5
600 0.567 0.173 52.2
700 0.616 0.188 48.5
800 0.663 0.202 45.4
824 0.674 0.206 44.7
894 0.706 0.215 43
Note Standard Conditions:
For attenuation: VSWR 1.0, cable temperature 20°C (68°F).
For average power: VSWR 1.0, ambient temperature 40°C (104°F), inner conductor temperature 115°C (239°F). No solar loading.

External Document Links

Notes

Related Products


HCH-550-1C

Hanger Type
Anchor bar 18-22mm (0.71-0.87")
Cable Type
Air Dielectric
Cable Size
5-1/2
Request quote

HCH-550-1L4

Hanger Type
Angle iron 40mm (1.575")
Cable Type
Air Dielectric
Cable Size
5-1/2
Request quote

HCH-550-1R

Hanger Type
Flat iron 6-12mm (0.24-0.47")
Cable Type
Air Dielectric
Cable Size
5-1/2
Request quote

EAR-550

Type of Grounding Kit
Pre-Formed Copper Strap
Package Quantity
1
Request quote

WF-550

Cable Size
5-1/2"
Request quote

HOIST2-L12

Cable Size
5-1/2"
Product Type
Hoisting Grip
Request quote

HCA550-50J

Applications
TV & Radio
HF Defense
Cable Solutions
Jacket Option
Outdoor
Fire Performance
Halogene Free
Request quote

WF-550

Cable Size
5-1/2"
Request quote

HCH-550-1C

Hanger Type
Anchor bar 18-22mm (0.71-0.87")
Cable Type
Air Dielectric
Cable Size
5-1/2
Request quote

HCH-550-1L4

Hanger Type
Angle iron 40mm (1.575")
Cable Type
Air Dielectric
Cable Size
5-1/2
Request quote

HCH-550-1R

Hanger Type
Flat iron 6-12mm (0.24-0.47")
Cable Type
Air Dielectric
Cable Size
5-1/2
Request quote

HCA550-50J

Applications
TV & Radio
HF Defense
Cable Solutions
Jacket Option
Outdoor
Fire Performance
Halogene Free
Request quote

EAR-550

Type of Grounding Kit
Pre-Formed Copper Strap
Package Quantity
1
Request quote

HOIST2-L12

Cable Size
5-1/2"
Product Type
Hoisting Grip
Request quote