Lifetime Connectivity

HA-FODC-LLBB-21-XX
HYBRIFLEX™;Hybrid jumper cable, Single-mode fibre, 6 mm² Power cable, Box to Radio Module; with LC Duplex Connectors;

Rev : J | Rev date : 11 Feb 2026

RFS' HYBRIFLEX™cabling solution for Remote Radio Head (RRH) combines optical fibre and DC power for RRHs in a single lightweight aluminum corrugated cable, making it the world’s most innovative solution for RRH deployments. It was developed to reduce installation complexity and cost at cellular sites.

HYBRIFLEX™cabling solutions allows mobile operators deploying RRH architecture to standardize RRH installation process and eliminates the need for and the cost of cable grounding.

The HYBRIFLEX™ jumper is part of the cabling solution for RRH’s. It consists of an armored part of length XX, a breakout part to the RRH and a breakout part to the distribution box. The breakout part to the RRH is outdoor ready and sealed according to IP68. 

The jumper cables can be ordered in 1m - 20 m armored length in 1 m incremental.

Features / Benefits

  • Aluminum corrugated armor with outstanding bending characteristics Minimizes installation time and enables mechanical protection and shielding

  • Built in animal protection Improves the reliability of the installation

  • Outer conductor grounding Eliminates typical grounding requirement and saves on installation costs

  • Lightweight solution and compact design Decreases tower loads

  • Optical fibre and power cables housed in single corrugated cable Saves CAPEX by standardizing RRH cable installation and reducing installation equipments

  • Outdoor polyethylene jacket Ensure long-lasting cable protection 

ha-fodc-llbb-21 new version.jpg
Structure
Cable Type Hybrid jumper
Mechanical Specifications
Outer Diameter Nominal 15.8mm (0.622in)
Cable Weight 0.235kg/m (0.158lb/ft)
Minimum Bending Radius 70mm (2.7in)
Minimum Bending Radius 125mm (5in)
Tensile Strength 150N (33.7lb)
DC Power Cable Specifications
Number of DC Pairs 1
Maximum DC-Resistance Power Cable 3.3Ω/km (1.51Ω/kft)
Cross Section of Power Cable 6 ()
Shielding Provided by Al armor
DC Wire Jacket Material Polyethylene grey / blue (colours will change to comply with British Standards)
DC Wire Jacket Thickness 0.5mm (0.02in)
DC Cable Jacket UV stable black PE
DC Standards (Meets or Exceeds) IEC 60228
Current Rating 42 (ambient 35°C)
Power Termination End 1 Only barewire without ferrule
Power Termination End 2 With ferrule for box connection
Cable Jacket
UV-Protection Individual and External Jacket External Jacket: to IEC 60754-1/-2, Inner Jacket, DC conductors + Fibre cables EN 50289-4-17:2015
Jacket Material UV stable black CPR class B2ca s1a d1 a1 + ISO 14001:2015 RoHS 2011/65/EU - China RoHS SJ/T 11364-2006 REACH (EC 1907/2006) UL1581 - UV Resistance Jacket
Armor Specifications
Armor Type Corrugated aluminum
Maximum DC-Resistance of Armor 2.42Ω/km (0.74Ω/kft)
Copper Equivalent Cross Section of Armor 8.45 ()
Diameter Corrugated Armor 13.8mm (0.543in)
F/O Cable Specifications
F/O Cable Type Tight buffer, G657A2 Single-mode
Number of F/O Pairs 2
Core/Clad 9 /125
Secondary Protection Nominal 900µm (0.036in)
Loss (db) Wavelength (nm)
0.4 1310
0.25 1550
Fiber Termination End 1 Duplex LC Connector
Fiber Termination End 2 Duplex LC Connector
Testing and Environmental
Storage Temperature -40°C to 85°C (-40°F to 185°F)
Operation Temperature -40°C to 85°C (-40°F to 185°F)
Installation Temperature -20°C to 50°C (-4°F to 122°F)
Variation Information
Model Number HA-FODC-LLBB-21-01 HA-FODC-LLBB-21-02 HA-FODC-LLBB-21-03 HA-FODC-LLBB-21-04
Length 1m (3.281ft) 2m (6.562ft) 3m (9.843ft) 4m (13.123ft)
Model Number HA-FODC-LLBB-21-05 HA-FODC-LLBB-21-06 HA-FODC-LLBB-21-07 HA-FODC-LLBB-21-08
Length 5m (16.404ft) 6m (19.685ft) 7m (22.966ft) 8m (26.247ft)
Model Number HA-FODC-LLBB-21-09 HA-FODC-LLBB-21-10 HA-FODC-LLBB-21-15 HA-FODC-LLBB-21-20
Length 9m (29.528ft) 10m (32.808ft) 15m (49.213ft) 20m (65.617ft)
Recommended Tools
Earthing Kit Hoisting Grip Clamps
Earthing: GKSPEED20-12P Boots for Nokia RRH: AOPC HA-AOPC-01 Boots for Ericsson RRH: IP-RC HA-FOPLUG-A-04
Clamps: single MBH-12S; double MBH-12D

Related Products


DB-T1-8Z-16B-0Z-03

Supported F/O Connections
16 pairs DLC
Request quote